Product
The integrated battery allows patients to move freely anywhere in the hospital for at least 50 minutes*.
Furthermore, heated and humidified respiratory therapy is available even during transport, ensuring stable treatment.
* After 20 minutes on AC power, when operating on battery power.
** Humidification may not be sufficient after 30 minutes.
for mobility
To address the potential problems of water overflow and backflow
during movement, we developed dedicated mobile accessories,
allowing us to design a highly complete mobile system.
We provide blowers and oxygen blenders to ensure a stable supply of oxygen to patients.
- Maintain and stably control oxygen concentrations between 21% and 100%.
- Provide stable oxygen therapy anytime, anywhere.
- Maximize convenience to improve the quality of care.
- Safeguards to minimize infection
Air flowing in from the outside is first filtered through an intake filter.
The patient then inhales air filtered through a bacterial filter.
Furthermore, the humidified air in the humidifier chamber is delivered
directly to the patient interface without passing through the device,
ensuring safety from contamination and eliminating the need for a separate
cleaning or disinfection process.
Dual oxygen inlet support
Supports both low pressure oxygen inlet and high pressure oxygen inlet
it can be applied in various environments
The OmniOx series offers a range of ventilators, from Critical Ventilators to BiPAP and HFNC (Uni-Flow, Bi-Flow),
enabling you to provide the right treatment to the right patient at the right time.
- Integrated humidifier, providing continuous heated and humidified ventilation in any treatment mode.
- Essential SpO2 monitoring and optional micropump nebulization solution
Based on MEKICS's independently developed ventilator technology,
the Flow Trigger function can be implemented with Critical Ventilator
level performance even when using an external exhalation valve.
New Standard of HFNC
Real-time flow monitoring
allows for optimal settings.
Provides efficient treatment
by maximizing patient comfort.
FiO₂ automatically adjusts
based on target SpO2₂ within
the clinician-defined range.
Beyond Boundaries
Compensates for leakage up to 60 LPM
and minimizes patient asynchronization.
Provides treatment modes
ranging from HF to IV