OmniOx

Beyond Innovation, Into Care Saving time and effort through continuous
respiratory care

Optimal Solution
Whenever Patient Need It

Depending on the patient's symptoms and condition, treatment modes can be easily switched by simply changing the interface and treatment mode.
Furthermore, this continuous care enables prompt treatment and response even for complex respiratory syndrome.

OmniOx Product Line

For Hospital For Home
OmniOx700 OmniOx750 OmniOx751
Color
Features
Battery -
Modes HF
NIV - Option
IV - Option Option
Functions
TSF -
BiFlow™ Option
PTIF
ROX Index
Cannula Fitting
Oxygen Inlet High Pressure -
Low Flow
* NIV : CPAP, bi-level
* IV: PCV, VCV, PSIMV, VSIMV, SPONT

New Standard of HFNC

PTIF Viewer

Real-time flow rate monitoring allows optimal setting of flow rate for each patient.

An efficient way to get accurate setting of HFNC

Conventional

Apply a consistent setting protocol
regardless of each patient's condition.

Time
Labor
Complicated
Setup Method

Intuitive/immediate setting application
according to each patient's condition and demand

Time
Labor
Intuitive and
instant
setup method
PTIF is an index that evaluates the patient's inspiratory flow rate (= Patient's demand flow).
It displays the equipment and patient's flow rates together, providing a basis for adjusting to exceed the patient's maximum
inspiratory flow rate, and allows for visual confirmation to enable appropriate flow setting.

BiFlow™

Providing efficient treatment by maximizing patient comfort

BiFlow™ reduces the patient's expiratory effort, improving respiratory efficiency and device adaptability.
It maintains the positive airway pressure effect and anatomical dead space washout of HFNC,
and synchronizes with the patient's breathing to reduce oxygen consumption.

During Inhalation

  • Provides high flow rates
  • Efficiently removes anatomical dead space
  • Preserves the benefits of high-flow nasal cannulas

During Exhalation

  • Provides relatively low flow rates
  • Reduces expiratory resistance
  • Prevent HFNC failure

TSF

Automatically adjusts FiO₂ according to target SpO₂ within the range set by the clinician

Automatically adjusts FiO₂ within the FiO₂ range set by the clinician
by comparing the measured SpO₂ with the target SpO₂, thereby preventing hypoxia and hyperoxia.
If SpO₂ measurement is unstable or impossible, it switches to the preset backup FiO₂.

OmniOx, Beyond Boundaries

Smart leak compensation

Compensates for leaks up to 60 LPM, minimizing patient discomfort and maximizing treatment efficiency.
If an unexpectedly large leak occurs, the leak level is quickly assessed and compensated for within a single breath, minimizing patient asynchronization.
Furthermore, if PEEP is not maintained, it is immediately compensated for and synchronized with the patient's breathing within one or two breaths.

Flexible modes to suit a range of patients

Provides treatment modes that cover up to invasive mode

Depending on the clinician's judgment, it may be used as a ventilator through
IV mode when the patient's breathing pattern must be completely controlled
or when other treatment methods are required.